Beckhoff Automation GmbH & Co. KG TX1200 — 9 Engineering Interface (ENI)

Engineering Interface (ENI) Requirements Optionally, project function blocks can also be excluded from management in the project database and saved exclusively locally, i.e. only with the project, as is traditionally the case. TX1200 256 Version: 1.3 Description Project For objects representing project-specific source information, e.g. shared function blocks within a project, important for multi-user operation. The 'Get All' command automatically fetches all objects of this category from the project directory of the database into the local project, even those that were not yet created there.

Shared objects For general-purpose, project-independent objects, such as block libraries, which are normally used by several users in different projects. Notice The 'Get All' command copies only those objects of this category from the project directory of the database to the local project that have already been created there. Compilation files For the project-specific compile information (e.g. symbol files) automatically generated by TwinCAT PLC Control, which is also required by other tools. For example, a visualization requires the variables of a programming system including the addresses, which, however, are only assigned during compilation.