Individual Components Options dialog box of the category Build The Selecting and Deselecting of the options debugging and online changes has no effects in TwinCAT for the PC at the moment. These settings can be made under TwinCAT options! With TwinCAT for Bus Terminal Controller this setting causes that no more breakpoints are possible. In exchange more program memory is available. When the Replace constants option is selected, the value of each constant is loaded directly, and in Online mode the constants are displayed in green. Forcing, writing and monitoring of a constant then is no longer possible.
If the option is deactivated, the value is loaded into a storage location via variable access (this does in fact allow writing the variable value, but implies longer processing time). If the Nested comments option is active, comments can be placed within other comments. Example: (* a:=inst.out; (* to be checked *) b:=b+1; *) Here, the comment that begins with the first bracket is not closed by the bracket following “checked,” but only by the last bracket. Create binary file of the application If the option Create binary file of the application is activated, a binary image of the generated code (boot project) is created in the project directory during compilation. File name: .bin.
By comparison, the command 'Online' 'Create Boot project' sets up the boot project on the controller. When an option is activated, a check appears next to the option. Actions hide programs This option is activated per default, when a new project is created. It means: If a local action has the same name like a global variable or a program, the following hierarchy is valid: local variable before local action before global variable before program. TX1200 52 Version: 1.3