Beckhoff Automation GmbH & Co. KG TX1200 — 4.2 Options

Individual Components You can choose to which Timing and what Extent the project is loaded into the controller system. Extent: The option Source code only exclusively involves just the project file (extension .pro). The option All files also includes files such as the associated library files, visualization bitmaps, configuration files, etc. The option Source code only (excluded compile info) involves like above the pure Source code, but without Compile info. Thus this function is a pure source filling. An Online change after the source upload from the PLC is not possible. This option is interesting for the BX platform, because of the less data range. Timing:

Using the option Implicit at load allows the selected file range to be automatically loaded into the controller system on the command ‘Online‘ ‘Download'. Using the option Notice at load offers a dialog, when the command ‘Online‘ ‘Download' is given, with the question ”Do you want to write the source code into the controller system?”. Pressing ‘Yes’ will automatically load the selected range of files into the controller system, or you can alternatively finish with ‘No’. Using the option Implicit on create boot project allows the selected file range to be automatically loaded into the controller system on the command 'Online' 'Create boot project'.

When using the option Only on demand the selected range of files must be expressly loaded into the controller system by giving the command ‘Online‘ ‘Sourcecode download'. The project which is stored in the controller system can be retrieved by using ‘File‘ ‘Open' with Open project from PLC. The files will be unpacked in the process. See Chapter 'File' 'Open' for details! Symbol configuration This form of symbol management exists only because of compatibility reasons und should only be used for the TwinCAT OPC Server. For all other cases exists a (at each compile) new created XML file with the name .tpy TX1200 55 Version: 1.3