Individual Components Possible Actions with Projects: 'Project' 'Build' + The project is compiled using 'Project' 'Build' . The compilation process is basically incremental, that is only changed POUs are recompiled. A non-incremental compilation can also be obtained if the command 'Project' 'Clear all' is first executed. For target systems that support Online Change, all POUs that will be loaded into the controller on the next download are marked with a blue arrow in the Object Organizer after compilation. The compilation process that is carried out with ' Project' 'Build' occurs automatically if the controller is logged-in via 'Online' 'Log-in'.
During compilation a message window is opened which shows the progress of the compilation process and any errors and warnings which may occur during compilation. Errors and warnings are marked with numbers. Using F1 you get more information about the currently selected error. A list of all error messages [ } 223] is to be found in the appendix. If the option Save before compilation is selected in the options dialog of the Load & Save category, the project is stored before compilation. The cross-references are created during compilation and are stored in the build information.
In order to apply the commands Browse Call Tree , Show Cross Reference and the commands Unused variables , Concurrent access and Multiple write access on output of the ' Project' 'Check' menu, the project must be rebuilt after a change. 'Project' 'Rebuild all' With ' Project' 'Rebuild all' unlike incremental compilation ( 'Project' 'Build' ) the project is completely recompiled. However, the download information will not be discarded, as is the case with the 'Clean all' command. 'Project' 'Clean All' This command deletes the information of the last download and the last compilation process.
After selecting the command, a dialog box appears indicating that login is no longer possible without a new download. Here the command can be canceled or confirmed. After 'Clean all' a login on the PLC project is only possible if the *.ri file with the project information from the last download was first explicitly saved outside the project directory (see 'Load Download- Information') and can now be reloaded prior to logging-in. Project' 'Load Download- Information' With this command the Download-Information belonging to the project can get reloaded, if it was saved to a directory different from that where the project is. After choosing the command the standard dialogue ' File Open' opens.
The Download-Information is saved automatically at each download to a file, which is named name> .ri and which is put to the project directory. This file is loaded, when the project is opened and at login it is used to check whether the PLC project is fitting to the currently opened TwinCAT PLC Control project (Id-check). Furthermore it is used to check, in which POUs the code has been changed. In systems which support the online change functionality, then only these POUs will be loaded to the PLC TX1200 73 Version: 1.3