TwinCAT NC Master Axes Dynamics 3.2 Dynamic profile with A+ = A- 5000.0 mm/s/s, R = 50000.0 mm/s/s, V = 1750.0 mm/s from 0.0 mm to 800.0 mm Dynamics 3.3 Dynamic profile with A+ = A- 5000.0 mm/s/s, R = 50000.0 mm/s/s, V = 2000.0 mm/s from 0.0 mm to 800.0 mm Table 1: Global dynamic parameters Notes on start parameters: 1. For orders of magnitude from J to A+ or A- in units of mm and Saf cycle time T should apply with suffi- ciently large distances: J « min(A+, A-) . (An example: with Saf- cycle time T = 1/1000 s , acceleration as well as deceleration A+ = A- = 10000 mm/s/s = 1/100 mm/T/T, jerk J = 100000 mm/s/s = 1/10000 mm/T/T results in J = 0.0001 " A+ = A-= 0.01 .) 2.
To ensure that the set acceleration A+ or deceleration A- is actually reached, the jerk J must at least correspond to the critical jerk : J ≥ max( (A+)І, (A-)І)/V . Table 2: Start parameters Notes on start parameters: TX1250 15 Version: 1.1 Dynamic parameters Meaning and boundary conditions Acceleration A+ Acceleration limit (A+ > 0.0) Deceleration A- Deceleration limit (A- > 0.0) Jerk J Amount of the acceleration change constant (J > 0.0) Start parameters Meaning and boundary conditions Target velocity V requested path set velocity (amount of the axis target velocity) (V > 0.0, V ≤ V max) _ Target position P Position to be approached P (P min ≤ P ≤ P max) _ _