TwinCAT NC Master Axes Partial compensation: start from 0.0 mm to 10,000.0 mm with V = 2000.0 mm/s Compensation A+ = 500.0 mm/s/s A- = 1000.0 mm/s/s, V = 500.0 mm/s, VP = 2000.0 mm/s, L = 2000.0 mm, D = 500.0 mm End position 10165.0 mm Full negative compensation: start from 0.0 mm to 10,000.0 mm with V = 2000.0 mm/s Compensation A+ = 500.0 mm/s/s A- = 1000.0 mm/s/s, V = 300.0 mm/s, VP = 2000.0 mm/s, L = 5000.0 mm, D = -250.0 mm End position 9750.0 mm Start parameters Position compensation: start parameters Notes on start parameters: 1. The compensation difference D may be positive (making up) or negative (deceleration). If D , (double) motion reversal is possible. 2. Process velocity .
If compensation is activated while the axis is traveling at its (global) target velocity, then VP should be set to equal this velocity. If the axis is not yet (no longer, not - Override -) at its global target velocity, VP should be set to the amount of the current local target velocity of the axis. TX1250 22 Version:
1.1 Start parameters Meaning and boundary conditions Compensation length L Distance, over which additional positioning occurs (L > 0.0) Compensation difference D Additional travel distance (D ≠ 0.0) Process velocity VP Velocity, to which the velocity increase refers (generally axis target velocity) (VP > 0.0) Velocity increase VK Permissible velocity increase/reduction relative to the process velocity (VK > 0.0) Acceleration AK+ Required acceleration increase relative to the global path acceleration (AK+ >0.0) Deceleration AK- Required deceleration increase relative to the global path deceleration (AK- > 0.0)