PMAC Product Guide When I6 is set to 1 or 3, an error number message can be reported along with the character. The message comes in the form of ERRnnn , where nnn represents the three-digit error number. If I3 is set to 1 or 3, there is a character in front of the message. When I6 is set to 1, the form of the error message is {error message} . This setting is the best for interfacing with host-computer driver routines. When I6 is set to 3, the form of the error message is {error message} . This setting is appropriate for use with the PMAC Executive Program in terminal mode. Currently, the following error messages can be reported: I7 In-Position Number of Cycles Range: 0 .. 255 Default:
0 Units: Background computation cycles (minus one) This parameter permits the user to define the number of consecutive scans that PMAC motors must satisfy all in-position conditions before the motor in-position bit is set true. This ensures that the motor is truly settled in the end position before executing the next operation, on or off PMAC. The number of consecutive scans required is equal to I7 + 1. PMAC scans for the in-position condition of each active motor during the housekeeping part of every background cycle which occurs between each scan of each enabled uncompiled background PLC (PLC 1- 31).
All motors in a coordinate system must have true in-position bits for the coordinate-system in- position bit to be set true. I-Variables 99 Error Problem Solution ERR001 Command not allowed during program execution (Should halt program execution before issuing command) ERR002 Password error (Should enter the proper password) ERR003 Data error or unrecognized command (Should correct syntax of command) ERR004 Illegal character:
bad value (>127 ASCII) or serial parity/framing error (Should correct the character and/or check for noise on the serial cable) ERR005 Command not allowed unless buffer is open (Should open a buffer first) ERR006 No room in buffer for command (Should allow more room for buffer -- DELETE or CLEAR other buffers) ERR007 Buffer already in use (Should CLOSE currently open buffer first) ERR008 MACRO Link Error Register X:$0798 holds the error value ERR009 Program structural error (e.g. ENDIF without IF) (Should correct structure of program) ERR010 Both over-travel limits set for a motor in the C.S.
(Should correct or disable limits) ERR011 Previous move not completed (Should Abort it or allow it to complete) ERR012 A motor in the coordinate system is open-loop (Should close the loop on the motor) ERR013 A motor in the coordinate system is not activated (Should set Ix00 to 1 or remove motor from C.S.) ERR014 No motors in the coordinate system (Should define at least one motor in C.S.) ERR015 Not pointing to valid program buffer (Should use B command first, or clear out scrambled buffers) ERR016 Running improperly structured program (e.g. missing ENDWHILE) (Should correct structure of program) ERR017 Motor(s) in C.S.
not at halted position to restart after / or \ command (Should move motor(s) back to halted position with J=)