PMAC Product Guide Examples: 1. Motor 1 using flags 1 with amp-enable output, and low-true amp fault disabling all motors: I125=$00C000 or I125=$C000 2. Motor 1 using flags 1 with direction output, and low-true amp fault disabling all motors: I125=$01C000 3. Motor 1 using flags 1 with amp-enable output, and low-true amp fault disabling only coordinate system motors: I125=$20C000 4. Motor 1 using flags 1 with direction output, and amp-fault disabled, with excess following error disabling all Coordinate System motors: I125=$31C000 5. Motor 1 using flags 5 with amp-enable output, and high-true amp fault disabling only this motor: I125=$C0C010 Ix26 Motor x Home Offset Range: -8,388,608 ..

8,388,607 Default: 0 Units: 1/16 Count This is the relative position of the end of the homing cycle to the position at which the home trigger was made. That is, the motor will command a stop at this distance from where it found the home flags and call this commanded location as motor position zero. This permits the motor zero position to be at a different location from the home trigger position, particularly useful when using an overtravel limit as a home flag (offsetting out of the limit before re- enabling the limit input as a limit). If large enough (greater than 1/2 times home speed times acceleration time) it permits a homing move without any reversal of direction. Note:

The units of this parameter are 1/16 of a count, so the value should be 16 times the number of counts between the trigger position and the home zero position. Example: To make motor zero position as 500 counts in the negative direction from the home trigger position, set Ix26 to -500 * 16 = -8000. Ix27 Motor x Position Rollover Range Range: 0 .. 8,388,607 Default: 0 Units: Counts This parameter permits position rollover on a PMAC rotary axis by telling PMAC how many encoder counts are in one revolution of the rotary axis. This lets PMAC handle rollover properly. When Ix27 is greater than zero, and motor x is assigned to a rotary axis (A, B, or C), rollover is active.

With rollover active, for a programmed axis move in Absolute ( ABS ) mode, the motor will take the shortest path around the circular range defined by Ix27 to get to the destination point. Axis moves in Incremental ( INC ) mode are not affected by rollover. When Ix27 is set to 0, there is no rollover. Rollover should not be attempted for axes other than A, B, or C. Jog moves are not affected by rollover. Reported motor position is not affected by rollover. (To obtain motor position information rolled over to within one motor revolution, use the modulo (remainder) operator, either in PMAC or in the host computer: e.g. P4=(M462/(I408*32))%I427) 116 I-Variables $C:

High-true amp fault enabled; only this motor killed on fault or excess following error $D: Amp fault disabled; only this motor killed on excess following error $E: High-true amp fault enabled; only this motor killed on fault or excess following error $F: Amp fault disabled; only this motor killed on excess following error