PMAC Product Guide I903, I908, ... I978 Encoder n Flag Select Control Encoder I-Variable 3 Range: 0 .. 3 Default: 0 Units: none This parameter determines which of the Flag inputs will be used for position capture (if one is used -- see I902 etc.): Typically, this parameter is set to zero because in actual use, the +/-LIMn and FAULTn flags create other effects that usually interfere with what is trying to be accomplished by the position capture. To capture on the +/-LIMn or FAULTn flags, either disable their normal functions with Ix25 or use a channel n where none of the flags is used for the normal axis functions.
The direction sense of the limit inputs is the opposite of what many people consider intuitive. That is, the +LIMn input, when taken high (opened), stops commanded motion in the negative direction; the -LIMn input, when taken high, stops commanded motion in the positive direction. It is important to confirm the direction sense of the limit inputs in actual operation. 128 I-Variables Setting Meaning 0 HMFLn (Home Flag n) 1 -LIMn (Positive Limit Signal n) 2 +LIMn (Negative Limit Signal n) 3 FAULTn (Amplifier Fault Signal n)