PMAC Product Guide J^* Function : Jog to specified variable distance from present actual position Scope : Motor specific Syntax : J^* This command causes the addressed motor to jog the distance specified in the motor’s variable jog position/distance register relative to the present actual position. Jogging acceleration and velocity are determined by the values of Ix19-Ix22 in force at the time of this command. Compare to J:* which is a jog relative to the present commanded position. The variable jog position/distance register is a floating-point register with units of counts. It is best accessed with a floating-point M-Variable.
The register is located at PMAC address L:$082B for motor 1, L:$08EB for motor 2, etc. The usual procedure is to write the destination position to this register by assigning a value to the M-Variable, then issuing the J^* command. PMAC will reject this command if the motor is in a coordinate system that is currently running a motion program (reporting ERR001 if I6 is 1 or 3). Examples: M172->L:$082B ; Define #1 variable jog position/distance reg.
#1HMZ ; Declare present position to be zero M172=3000 ; Assign distance value to register #1J^* ; Jog Motor 1 this distance; if following error at command was 3, end command position ; will be 2997 #1J^* ; Jog Motor 1 this distance; if following error at command was 2, end command position ; will be 5995 M172=P1*SIN(P2) ; Assign new distance value to register #1J^* ; Jog Motor 1 this distance #1J= ; Return to prejog target position {jog command}^{constant} Function : Jog until trigger Scope : Motor specific Syntax :
J=^{constant} J={constant}^{constant} J:{constant}^{constant} J^{constant}^{constant} J=*^{constant} J:*^{constant} J^*^{constant} where {constant} after the ^ is a floating point value specifying the distance from the trigger to which to jog after the trigger is found, in encoder counts This command format permits a jog-until-trigger function. When the ^{constant} structure is added to any definite jog command, the jog move can be interrupted by a pre-defined trigger condition, and the motor will move to a point relative to the trigger position as specified by the final value in the command. The indefinite jog commands J+ and J- cannot be turned into jog-until-trigger moves.
Jog-until-trigger moves are similar to homing search moves, except they have a definite end position in the absence of a trigger and they do not change the motor zero position. Online Commands 171