PMAC Product Guide MFLUSH Function : Clear pending synchronous M-Variable assignments Scope : Coordinate-system specific Syntax : MFLUSH This command permits the user to clear synchronous M-Variable assignment commands that have been put on the stack for intended execution with a subsequent move (without executing the commands). As an on-line command, it is useful for making sure pending outputs are not executed after a program has been stopped. Examples: / ; Stop execution of a program MFLUSH ; Clear M-Variable stack B1R ; Start another program; formerly pending M-variables will not execute O{constant} Function : Open loop output Scope : Motor specific Syntax :

O{constant} where {constant} is a floating-point value representing the magnitude of the output as a percentage of Ix69 for the motor, with a range of +/-100. This command causes PMAC to put the motor in open-loop mode and force an output of the specified magnitude, expressed as a percentage of the maximum output parameter for the motor (Ix69). This command is commonly used for set-up and diagnostic purposes (for instance, a positive O command must cause position to count in the positive direction, or closed-loop control cannot be established), but it can also be used in actual applications.

If the motor is not PMAC-commutated, this command will create a DC output voltage on the single DAC for the motor. If the motor is commutated by PMAC, the commutation algorithm is still active and the specified magnitude of output is apportioned between the two DAC outputs for the motor according to the instantaneous commutation phase angle. If the value specified is outside the range +/-100, the output will saturate at +/-100% of Ix69. Closed-loop control for the motor can be re-established with the J/ command. It is a good idea to stop the motor first with an O0 command if it has been moving in open-loop mode.

To perform a variable O -command, define an M-Variable to the filter result register (X:$003A, etc.), command an O0 to the motor to put it in open-loop mode, then assign a variable value to the M-Variable. This technique will even work on PMAC-commutated motors. PMAC will reject this command if the motor is in a coordinate system that is currently running a motion program (reporting ERR001 if I6 is 1 or 3). Examples: O50 ; Open-loop output 50% of Ix69 for addressed motor #2O33.333 ; Open-loop output 1/3 of Ix69 for Motor 2 O0 ; Open-loop output of zero magnitude J/ ; Re-establish closed-loop control Online Commands 181