Ramsey Electronics UP24B — Ramsey UP24B Control Commands and Driver/Software Manual PDF

Get Commands Command details G EL Get elevation Explanation: Gets the current elevation in the current units with offset added. Example: G EL sent 1203.5ft returned G PR Get Pressure Explanation: Gets the current air pressure in the current units with offset added. Example: G PR sent 1003.5213Pa returned G OP Get Offset Pressure. Explanation: Gets the offset that is added to the air pressure readings in the current units. Example: G OP sent 1.5200Pa returned G OE Get Offset Elevation. AR2 16 Command: Description:

G EL Get elevation G PR Get pressure G OP Get offset pressure G OE Set offset elevation G VB Get supply voltage G CH Get entire chart (in CSV format) G PS Get pressure stats (in CSV format) G ES Get elevation stats (in CSV format) G PU Get Pressure Units and index G EU Get Elevation Units and index G SR Get Sample Rate and index G SD Get Screen dump