sinee — 6.2Table of functional parameters

User Manual of EM730 Series Inverter 120 F14.37 Speed integral time constant ASR T1 0.000~30.000 0.000: no integral s 0.200 ● 0x0E25 F14.38 _ Speed proportional gain ASR P2 0.00~100.00 8.00 ● 0x0E26 F14.39 _ Speed integral time constant ASR T2 0.000~30.000 0.000:

no integral s 0.300 ● 0x0E27 F14.40 _ Switching frequency 1 0.00 to switching frequency 2 Hz 5.00 ● 0x0E28 F14.41 Switching frequency 2 switching frequency 1 to maximum frequency F00.16 Hz 10.00 ● 0x0E29 F14.42 No-load current gain of motor 2 50.0~300.0 % 50.0 ● 0x0E2A F14.43 Filtering time constant of speed loop output 0.000 ~ 0.100 s 0.001 ● 0x0E2B F14.44 Vector control slip gain 50.00~200.00 % 100.0 0 ● 0x0E2C F14.45 Upper limit source selection of speed control torque 0: set by F06.10 and F06.11 1: AI1 2: AI2 3: reserved 4: reserved 5: communication setting (percentage) 6: The larger of AI1 and AI2 7:

The smaller of AI1 and AI2 0 〇 0x0E2D F14.46 Upper limit of speed control motor torque 0.0 ~ 250.0 % 165.0 ● 0x0E2E F14.47 Upper limit of speed control brake torque 0.0 ~ 250.0 % 165.0 ● 0x0E2F F14.48 Excitation current proportional gain ACR-P1 0.00 ~100.00 0.50 ● 0x0E30 F14.49 Excitation current integral time constant 0.00 ~ 600.00 0.00: no integral ms 10.00 ● 0x0E31