User Manual of EM730 Series Inverter 13 X5 can be used as the high-speed pulse input (max 100kHZ). Analog input terminal 2-channel analog inputs: One (AI1) voltage source: -10 to 10V input; One channel (AI2): 0 to 10V input voltage or 0 to 20mA input current optional; Digital output terminal Multi-function output of one open collector and one relay Maximum output current of the collector: 50mA; Relay contact capacity: 250VAC/3A or 30VDC/1A, EA-EC: normally open; EB-EC: normally closed Analog output terminal One multi-function analog terminal output M1:
0-10V/0-20mA multi-function analog output terminal Keyboard LED display The LED digital tube displays relevant information about the inverter. Protection Protective Function Short circuit, overcurrent, overvoltage, undervoltage, phase loss, overload, overheat, load loss, external protection, etc. Use conditions Location Indoor, at an altitude of less than 1 km, free of dust, corrosive gases and direct sunlight. When the altitude is higher than 1km, it is derated by 1% per 100m. The maximum allowable altitude is 3km. Applicable environment -10℃ to +50℃, 5% to 95%RH (no condensation). When the ambient temperature exceeds 50°C, it needs to be derated by 1.5% per 1°C temperature rise.
The maximum allowable ambient temperature is 60°C. Vibration Less than 0.5g Storage environment -40℃~+70℃ Installation method Wall-mounted or installed in the cabinet Levels of protection IP20/IP21 (with plastic baffle) Cooling method Forced air cooling