User Manual of EM730 Series Inverter optional groups of parameters in total. The larger the set value of F06.37, the larger the proportional gain is, the smaller the integral time is, and the more intense the speed PID regulation is. The smaller the set value of F06.37, the weaker the speed PID regulation is. The default settings of low frequency optimization options of the synchronous motor are suitable for most applications. If a larger torque is required at the low frequency, you can enable the IF mode. Tuning parameters for speed tracking of the synchronous motor.
7.8 F07 protection parameter group 218 Function code Function code name Parameter description Unit Default setting Attribute Mailing address F06.41 Open-loop low-frequency processing of synchronous motor 0: VF 1: IF 2:
IF in start and VF in stop 0 〇 0x0629 F06.42 Open-loop low-frequency processing range of synchronous motor 0.0 ~ 50.0 % 8.0 〇 0x062A F06.43 IF injection current 0.0 ~ 600.0 % 80.0 〇 0x062B Function code Function code name Parameter description Unit Default setting Attribute Mailing address F06.46 Speed tracking proportional gain of synchronous motor 0.00 ~ 10.00 1.00 〇 0x062E F06.47 Speed tracking integral gain of synchronous motor 0.00 ~ 10.00 1.00 〇 0x062F F06.48 Filtering time constant of speed tracking of synchronous motor 0.00 ~ 10.00 ms 0.40 〇 0x0630 F06.49 Speed tracking control intensity of synchronous motor 1.0 ~ 100.0 5.0 〇 0x0631 F06.50 Speed tracking control threshold of synchronous motor 0.00 ~10.00 0.20 〇 0x0632 F06.51 Injection current (Iq) rise time of synchronous motor 0.010 ~ 1.000 S 5.0 〇 0x0633 F06.82 Udc filtering time constant 0~1500.0 ms 2.0 ● 0x0652 Function code Function code name Parameter description Unit Default setting Attribute Mailing address F07.00 Protection shield E20 * E13 E06 * E04 E07 E08 0*00*0 〇 0x0700