User Manual of EM730 Series Inverter F12.17 and F12.18 are used together to check the cumulative operating time of the inverter from delivery to the current moment (the inverter should be in the running status). The cumulative power-on time is accurate to one minute and nearly 65536 hours (about 7.5 years) at most. If F12.17=47 and F12.18=39, it means that the current inverter has been running for 1 day, 23 hours and 39 minutes. ★ This parameter can be viewed only and cannot be changed or cleared. It is used to view the rated power, rated voltage and rated current of the current inverter. ★ This parameter is can be viewed only and cannot be changed.
It is used to view the software version of the current inverter. ★ This parameter is can be viewed only and cannot be changed.
263 Function code Function code name Parameter description Unit Default setting Attribute Mailing address F12.19 Rated power of inverter 0.40 ~ 650.00 kW Depending on the motor type × 0x0C13 F12.20 Rated voltage of inverter 60 ~ 690 V Depending on the motor type × 0x0C14 F12.21 Rated current of inverter 0.1 ~ 1500.0 A Depending on the motor type × 0x0C15 Function code Function code name Parameter description Unit Default setting Attribute Mailing address F12.22 Performance software S/N 1 XXX.XX XXX.XX × 0x0C16 F12.23 Performance software S/N2 XX.XXX XX.XXX × 0x0C17 F12.24 Functional software S/N 1 XXX.XX XXX.XX × 0x0C18 F12.25 Functional software S/N 2 XX.XXX XX.XXX × 0x0C19 F12.26 Keyboard software serial number 1 XXX.XX XXX.XX × 0x0C1A F12.27 Keyboard software serial number 2 XX.XXX XX.XXX × 0x0C1B