sinee — 7.18Virtual I/O Function Parameter Group of F17 Group

User Manual of EM730 Series Inverter The terminals VX1 to VX8 essentially have the same function, but there are no corresponding physical terminals actually. They all have the positive and negative logic functions. The terminals VX1 to VX4 have the delay function, and their statuses can be confirmed in the same way. They can be set separately. The terminal VX1 is taken as an example below.  When F17.09=xxxxxxx0, the VX1 status is the same as the VY1 output status. As stated literally, the status of the virtual input terminal is the same as that of the virtual output terminal, so this should be used in conjunction with the virtual output terminal.

310 positive/negative logic VX 7 VX 6 VX 6 VX 5 VX 4 VX 3 VX 2 VX 1 00000 0: positive logic, valid in the closed state/invalid in the open state 1:

negative logic, invalid in the closed state/valid in the open state F17.11 VX1 valid delay time 0.000~30.000 s 0.000 ● 0x110B F17.12 VX1 invalid delay time 0.000~30.000 s 0.000 ● 0x110C F17.13 VX2 valid delay time 0.000~30.000 s 0.000 ● 0x110D F17.14 VX2 invalid delay time 0.000~30.000 s 0.000 ● 0x110E F17.15 VX3 valid delay time 0.000~30.000 s 0.000 ● 0x110F F17.16 VX3 invalid delay time 0.000~30.000 s 0.000 ● 0x1110 F17.17 VX4 valid delay time 0.000~30.000 s 0.000 ● 0x1111 F17.18 VX4 invalid delay time 0.000~30.000 s 0.000 ● 0x1112 Function code Function code name Parameter description Unit Default setting Attribute Mailing address F17.09 VX1~VX8 status setting options D7 D6 D5 D4 D3 D2 D1 D0 000 00000 〇 0x1109 VX8 VX7 VX6 VX5 VX4 VX3 VX2 VX1 0:

the VXn status is the same as VYn output status 1: status set by F17.10 F17.10 VX1~VX8 status setting D7 D6 D5 D4 D3 D2 D1 D0 000 00000 ● 0x110A VX8 VX7 VX6 VX5 VX4 VX3 VX2 VX1 0: invalid 1: valid