sinee — 7.22Water supply application macro description

User Manual of EM730 Series Inverter 346 0 ~ 65000 (F15.13=2) F00.15 Deceleration time 1 0.00 ~ 650.00 (F15.13=0) 0.0 ~ 6500.0 (F15.13=1) 0 ~ 65000 (F15.13=2) s 15.00 F00.16 Maximum frequency 1.00~600.00/1.0~3000.0 Hz 50.00 F00.18 Upper frequency limit lower frequency limit F00.19 to maximum frequency F00.16 Hz 50.00 F00.19 Lower frequency limit 0.00 to upper frequency limit F00.18 Hz 0.00 F00.21 Reverse control 0: allow forward/reverse running 1: prohibit reversing 1 F00.30 Load Type 1: Light load 1 F02.00 X1 Digital input function selection 1: Run terminal RUN 1 F02.01 X2 Digital input function selection 23:

External fault input Can be connected to the external water shortage signal terminal 23 F02.37 Curve 2 Minimum Input -10.00V~F02.39 V 0.00 F02.38 Curve 2 Minimum input corresponding to Given –100.0~+100.0 % 0.0 F02.39 Curve 2 Maximum Input F02.37~10.00V V 10.00 F02.40 Curve 2 Maximum input corresponding to Given –100.0~+100.0 % 100.0 F02.62 Analog input AI1 type selection 0:0~10V 4:0~5V 0 F02.63 Analog input AI2 type selection 0:0~10V 1:4~20mA 2:0~20mA 4:0~5V 0 F03.00 Y1 output function 59: Sleep indication 59