User Manual of EM730 Series Inverter function code following the serial number function code has been successfully modified. In the Level 3 menu, press the ESC key to abandon parameter modifications. 4.2.2 User-defined mode ( --U-- ) Enter the F11 group of function codes from the full menu mode. Then the user can arbitrarily set the shortcut for the parameter to be accessed frequently. When F11.00 is enabled for the first time, U00.00 will be displayed by default, meaning that the function code defined by default for F11.00 is F00.00. The lowest cursor bit will flicker. The user can set any function code, similar to the function code selection in the Level 2 menu.
After setting, press the ENTER key to save it and enter the user-defined menu mode to display the set function code. For example, F11.00 is set to U00.07 and F11.01 to U00.09. F11.00 and F11.01 will be defined as F00.07 and F00.09, respectively. They are distinguished by U and F. U indicates that this function code is user-defined, as shown in Fig. 4-4. Fig. 4- 4 Example of User-defined Mode Setting to enter the Level 2 menu. The Level 2 menu only display 32 user-defined parameters in the F11 group. The user can enter the F11 group from the full menu mode to set these function codes.
In the user-defined mode, press the ENTER key After the function codes are defined in the F11 group, enter the user-defined mode. Then 56