User Manual of EM760 High-Performance Inverter F02.63 =4: 0~5V AI2 is the voltage type, with a range of 0-5V. The input voltage (0-5V) corresponds to the setting 0%-100%. 0V corresponds to 0%, and +5V corresponds to 100%. F02.64 and F02.63 share the same instructions, and so do F02.65 and F02.62. 6.5.8 Analog output terminal (AO) M1 and M2 are multi-function analog output terminals. Their functions can be defined separately by setting the value of the function code F03.21 and F03.22. For example, ifF03.21=0 is defined, the function of the M1 terminal is to output the “operating frequency (absolute value)”. The current |operating frequency| is reflected by the output voltage.
If the operating frequency increases from 0.00Hz to 50.00Hz (assuming F00.16=50.00), the voltage of the M1 output port will increase from 0.00V to 10.00V under the default conditions, showing the same change trend. Specific options are described in the table below.
Table 6-15 Function List of Multi-function Analog Output Terminal 145 Function code Function codename Parameter description Unit Default setting Attribute F03.21 Options ofanalog output M1 See Table 6-15 Function List of Multi- function Analog Output Terminal 0 〇 F03.22 Options ofanalog output M2 2 〇 Settings Function Description 0 Operating frequency (absolute value) 0.00Hz to Fmax, corresponding to the output 0.0% to 100.0% 1 Set frequency (absolute value) 0.00Hz to Fmax, corresponding to the output 0.0% to 100.0% 2 Output torque (absolute value) 0.0% to 200.0%, corresponding to the output 0.0% to 100.0% 3 Set torque (absolute value) 0.0% to 200.0%, corresponding to the output 0.0% to 100.0% 4 Output current 0.0A to 2*Ie, corresponding to the output 0.0% to 100.0% 5 Output voltage 0.0V to 1.5*Ue, corresponding to the output 0.0% to 100.0% 6 Bus voltage 0V to about 2.63*Ue, corresponding to the output 0.0% to 100.0% (That is, for the 220V driver, 579V corresponds to the output 100.0%; for the 380V driver, 1000V corresponds to the output 100.0%, and for the 660V driver, 1736V corresponds to the output 100.0% Drivers at different voltage levels have the same output voltage at their rated voltages.) 7 Output power 0.00kW to 2*Pe, corresponding to the output 0.0% to 100.0% 8 AI1 Output the actual input voltage, instead of the offset result.
0.0% to 100.0%, corresponding to the output 0.0% to 100.0% 9 AI2