User Manual of EM760 High-Performance Inverter 6.9.1.5 High-speed motor application F16.00=7: High-speed motor application The inverter can be used to configure the parameters ofthe corresponding function code for the high-speed motor application macro. 6.9.1.6 Communication macro of EM100 and EM303 F16.00=9: EM100 communication macro The inverter can be used to configure the parameters of the corresponding function code for the EM100 communication macro.
If you were using the EM100 model combined with Modbus communication, set F16.00=9, and you can replace EM100 directly without altering customer’s PLC program while securing common communication functions, including writing frequency and reading output current/frequency and inverter running state. F16.00=10: EM303B communication macro The inverter can be used to configure the parameters of the corresponding function code for the EM303B communication macro.
If you were using the EM303B model combined with Modbus communication, set F16.00=10, and you can replace EM303B directly without altering customer’s PLC program while securing common communication functions, including writing frequency and reading output current/frequency and inverter running state; 176 Function code Function codename Parameter description Unit Current value of application macro Attribute F00.01 Drive control mode of motor 1 0: V/F control (VVF) 0 O F00.31 Frequency resolution 1: 0.1Hz (speed unit: 10rpm) 1 O F00.23 Carrier frequency 1.0-16.0 (rated power of the inverter: 0.75- 4.00kW) kHz 8 ● F00.24 Automatic adjustment of carrier frequency 0:
Invalid 0 O F05.10 Compensation gain of V/F stator voltage drop 0.00~200.00 % 0.00 ● F05.11 V/F slip compensation gain 0.00~200.00 % 0.00 ● F07.00 Protection shield E20 E22 E13 E06 E05 E04 E07 E08 0: valid protection 1: shielded protection 00000001 O Function code Function code name Current value ofEM100 communication macro Corresponding function code of EM100 communication macro address Current value of EM303B communication macro Corresponding function code of EM303B communication macro address Attribute F00.04 Options of main frequency source A 0 0 O F45.00 Enable Modbus communication free mapping 1 1 ●