sinee — 6.9.2 Winding and unwinding application with sw

User Manual of EM760 High-Performance Inverter 6.9.2 Winding and unwinding application with swing lever F27.00=0 Winding mode: This mode can be used for winding. After the default settings are restored, the parameters will be restored for winding applications. F27.00=1 Unwinding mode: This mode can be used for unwinding. After the default settings are restored, the parameters will be restored for unwinding applications. F27.00=2 Wire drawing mode: This mode can be used for wire drawing. After the default settings are restored, the parameters will be restored for wire drawing applications. F27.00=3 Straight wire drawing machine mode:

This mode can be used for the straight wire drawing machine. After the default settings are restored, the parameters will be restored for the straight wire drawing machine. 179 Function code Function code name Parameter description Unit Default setting Attribute F27.00 Application macro 0: Winding mode 1: Unwinding mode 2: Wire drawing mode 3: Straight wire drawing machine mode 0 O Function code Description 0: Winding mode 1: Unwinding mode 2: Wire drawing mode 3: Straight wire drawing machine mode Set F16.00=3, select the operation mode and restore the default settings. The application parameters are automatically set to the following default values.

Basic parameters (the motor parameters need to be set manually and subject to static self-learning) F00.02 Command source 1: Terminal control 1: Terminal control 1: Terminal control 1: Terminal control F00.03 Terminal control mode 0: terminal RUN 0: terminal RUN 0: terminal RUN 0: terminal RUN F00.04 Main frequency A 1: AI1 setting 0: Digital setting 1: AI1 1: AI1 setting F00.05 Auxiliary frequency B 10: process PID 10: process PID 10: process PID F00.06 Frequency source 6: auxiliary frequency B + feedforward calculation 6: auxiliary frequency B + feedforward calculation 6:

auxiliary frequency B + feedforward calculation F00.07 Main frequency A setting 75.00Hz F00.14 Acceleration time 1.00s 1.00s 70.00s 1.00s F00.15 Deceleration time 1.00s 1.00s 70.00s 1.00s F00.16 Maximum frequency 75.00Hz 75.00Hz 75.00Hz 50.00Hz F00.18 Upper frequency limit 75.00Hz 75.00Hz 75.00Hz 50.00Hz