User Manual of EM760 High-Performance Inverter 300 F06.28 Frequency of low frequency band of injection current 0.00-100.00 (100.00 is the rated frequency of the motor) % 10.00 ● 0x061C F06.29 Injection current of low frequency band 0.0-200.0 (100.0 is the rated current of the motor) % 40.0 ● 0x061D F06.30 Regulator gain of low frequency band of injection current 0.00~10.00 0.50 ● 0x061E F06.31 Regulator integral time of low frequency band of injection current 0.00~300.00 ms 10.00 ● 0x061F F06.32 Frequency of high frequency band of injection current 0.00-100.00 (100.00 is the rated frequency of the motor) % 20.00 ● 0x0620 F06.33 Injection current f high frequency band 0.0-30.0 (100.0 is the rated current of the motor) % 8.0 ● 0x0621 F06.34 Regulator gain of high frequency band of injection current 0.00~10.00 0.50 ● 0x0622 F06.35 Regulator integral time of high frequency band of injection current 0.00~300.00 ms 10.00 ● 0x0623 F06.36 Magnetic saturation coefficient of synchronous motor 0.00~1.00 0.60 O 0x0624 F06.37 Stiffness coefficient of speed loop 0~20 11 ● 0x0625 F06.40 Amplitude of injected reactive current of synchronous motor -50.0~+50.0 % 10.0 O 0x0628 F06.41 Open-loop low- frequency of processing synchronous motor 0:
VF 1: IF 2: IF in start and VF in stop 3: Throughout SVC 0 O 0x0629 F06.42 Open-loop low- frequency processing range of synchronous motor 0.0~50.0 % 8.0 O 0x062A F06.43 IF injection current 0.0~600.0 % 80.0 O 0x062B