sinee — Chapter 11 Function Code Table

User Manual of EM760 High-Performance Inverter 315 0: Initialization 1: Pre-operation 2: Operation 3: Stop 4: CANopen communication abnormality 5: Modbus communication abnormality 6: Factory testing Hundreds place: Reserved F10.48 Communication card software version × 0x0A30 F10.49 Quantity of process data received 1~16 2 × 0x0A31 F10.50 Quantity of process data sent 1~16 2 × 0x0A32 F10.51 Selection of address setting mode for process data 1: Master station 0: Keyboard setting configuration 0 × 0x0A33 F10.52 Selection of communication card manual resetting 0: Invalid 1: valid 0 × 0x0A34 F10.56 Options of 485 EEPROM writing 0-10: default operation (for commissioning) 11:

writing not triggered (available after commissioning) 0 O 0x0A38 F10.57 Enabling of SCI sending timeout resetting 0: invalid resetting 1: valid resetting 1 ● 0x0A39 F10.58 Delay time of SCI sending timeout resetting 110~10000 150 ● 0x0A3A F10.61 SCI response option 0: Reply to both read and write commands 1: Reply to write commands only 2: No reply to both read and write commands 0 O 0x0A3D F10.62 CANopen self- check identification code 0~65535 0 × 0x0A3E