User Manual of EM760 High-Performance Inverter 327 F14.69 Injection current f high frequency band 0.0-30.0 (100.0 is the rated current of the motor) % 8.0 ● 0x0E45 F14.70 Regulator gain of high frequency band of injection current 0.00~10.00 0.50 ● 0x0E46 F14.71 Regulator integral time of high frequency band of injection current 0.00~300.00 ms 10.00 ● 0x0E47 F14.72 Open-loop low- frequency of processing synchronous motor 0: VF 1: IF 2: IF in start and VF in stop 3:
Throughout SVC 0 O 0x0E48 F14.73 Excitation current setting for frequency switching from F3 to F4 0.0~100.0 % 50.0 ● 0x0E49 F14.74 Switching frequency 3 0.0~50.00 Hz 6.00 O 0x0E4A F14.75 Switching frequency 4 0.0~60.00 Hz 10.00 O 0x0E5B F14.76 Steady load torque and current setting 0.0~150.0 % 30.0 ● 0x0E5C F14.77 Acceleration/decele ration time options ofmotor 2 0: the same as motor 1 1: acceleration and deceleration time 1 2: acceleration and deceleration time 2 3: acceleration and deceleration time 3 4:
acceleration and deceleration time 4 0 O 0x0E4D F14.78 Maximum frequency of motor 2 1.00~600.00 Hz 50.00 O 0x0E4E F14.79 Upper frequency limit ofmotor 2 Lower limit frequency F00.19 to maximum frequency F14.78 Hz 50.00 ● 0x0E4F F14.80 V/F curve setting of motor 2 0: straight line V/F 1: multi-point broken line V/F 2: 1.3-power V/F 3: 1.7-power V/F 4: square V/F 5: VF complete separation mode (Ud = 0,Uq = K * t = voltage of separation voltage source) 6: VF semi-separation mode (Ud = 0, Uq = K * t = F/Fe * 2 * voltage of separation voltage source) 0 O 0x0E50 F14.81 Multi-point VF frequency F1 of motor 2 0.00~F14.83 Hz 0.50 ● 0x0E51