arbitrary wave and noise. If need to change the waveform, press Param ModWave . Square wave: duty ratio is 50% Rising Ramp Wave: symmetry degree is 100% Falling Ramp Wave: symmetry degree is 0% Arbitrary Wave: when arbitrary wave is modulated waveform, DDS function generator limits arbitrary wave length as 4kpts 2) External Source When modulation source is external, parameter list will hide the modulation wave option and modulation frequency option, and carrier waveform will be modulated by an external waveform. AM modulation depth is controlled by ±5V signal level of external modulation input terminal Modulation In connector).
For example, if modulation depth value is set to 100%, AM output amplitude is the maximum when external modulation signal is +5V, AM output amplitude is the minimum when external modulation signal is -5V. Set Modulation Wave Frequency When modulation source is internal, frequency can be reset. Default of modulation wave frequency is 100Hz. Press Param Mod Freq to change. Modulation frequency range: 2 MHz~1MHz. When modulation source is external, parameter list will hide the modulation wave option and modulation frequency option, and carrier waveform will be modulated by an external waveform. The range of external signal frequency is 0Hz~ 20 kHz.
Set Modulation Depth Modulation depth indicates the extent of amplitude variation which is expressed as percentage. Settable range of AM modulation depth is 0% ~ 120%, and the default is 100%. When modulation depth is set to 0%, the constant amplitude (half of the carrier wave amplitude)is output. Output amplitude changes as modulation waveform changes when modulation depth is set to 100%. The instrument output a peak-peak voltage less than ±5V (50Ω terminal) when modulation depth is more than 100%. If need to change, press Param Depth in amplitude function interface.
When modulation source is external, output amplitude of the instrument is controlled by ± 5V signal level of external modulation input terminal (Modulation In connector) in rear panel. For example, if modulation depth value in parameter list has been set to 100%, AM output amplitude is the maximum when external modulation signal is +5V, AM output amplitude is the minimum when external modulation signal is -5V. Comprehensive Example Set a sine wave with 200Hz from the internal of the instrument as a modulation signal and a square wave: frequency =10 kHz, amplitude of 200mVpp and duty ratio of 45% as a carrier wave signal. Finally, set modulation depth to 80%.
Specific steps are seen as following: Noise: White Gauss noise 3) Enable Amplitude Modulation (AM) Function Press Menu Mod Type AM in turn. 28 UTG2000B Series