First make the instrument run in BPSK mode, and then set an internal sine wave of 2kHz and 2Vpp as carrier signal. Finally set carrier phase and initial modulation phase to be 90 ˚, frequency between phases to be 1kHz and PN code to be PN15. The specific steps are as follows: Use BPSK function Press s Menu Type BPSK successively (press soft key Type to select if Type is not highlighted) to use BPSK function. Set carrier signal parameters Press Carrier Type Sine to select carrier signal as sine wave. The default carrier signal is sine wave, so it is unnecessary to change in this example. You can press Param to setup the parameters. 64 UTG2000B Series