In case of internal modulation source, modulation wave can be sine wave, square wave, rising ramp wave, falling ramp wave, arbitrary wave and noise, and is sine wave by default. After you use PWM function, you can see that modulation wave is sine wave by default. You can change it with multi-functional knob on interface for using PWM function or by pressing Param ModWave Square wave: duty ratio is 50% Rising ramp wave: degree of symmetry is 100% Falling ramp wave: degree of symmetry is 0% Arbitrary wave: when selecting arbitrary wave as modulation waveform, function/arbitrary waveform generator limits length of arbitrary wave to 4kpts by automatic test count. Noise:
white Gaussian noise 2) External source In case of external modulation source, modulation wave and frequency will be hidden in parameter list, when an external waveform will be used to modulate carrier waveform. Duty ratio deviation of PWM is controlled by ±5V signal level on external analog modulation input terminal (Modulation In connector) of back panel. For example, if duty ratio deviation in parameter list is set to be 15%, duty ratio of carrier signal (pulse wave) increases by 15% when external modulation signal is +5V. Lower external signal level generates less deviation. Set modulation frequency When modulation source is internal, frequency of modulation wave can be modulated.
After enabling PWM function, default of modulation wave frequency is 100Hz. Press Param ModFreq to change. Modulation frequency range: 2mHz~1MHz. When modulation source is external, parameter list will hide the modulation wave option and modulation frequency option, and carrier waveform will be modulated by an external waveform(impulse wave). The range of modulation signal input from external is 0Hz~ 20Hz. Set duty ratio deviation Duty ratio deviation is deviation of modulated waveform from the current carrier duty ratio. The range of PWM duty ratio is 0%~49.99%, 20% by default.
You can change it with multi-functional knob and direction key on interface for using PWM function or by pressing Param DutyDev Duty ratio deviation is change in duty ratio of modulated waveform relative to original pulse waveform (%). Duty ratio deviation should not be more than current duty ratio of pulse wave. The sum of duty ratio deviation and current duty ratio of pulse wave must be 99.99%. Duty ratio deviation is restricted by minimum duty ratio of pulse wave and the current edge time.
Comprehensive example First make the instrument run in PWM mode, and then set an internal sine wave of 1kHz as modulation signal and a pulse wave with frequency of 10kHz, amplitude of 2Vpp, duty ratio of 50% and rising/falling time of 100ns as carrier signal. Finally set duty ratio deviation to be 40%. The specific steps are as follows: 1) Use PWM function Press Menu Mod PMW successively (if Type is not highlighted, it may be necessary to press soft key Type twice to display the next screen of sub-tags) to use PWM function. UTG2000B Series 87 Type → y Type