4-2 Function Mode •You can also select a multi-step speed by turning on/off the multi-step speed terminals (CF1 to CF4) and set the multi-step speed frequency with F001. 11th Frequency reference from the Digital Operator or the external analog input terminal 4 CF1 CF2 Functions CF3 CF4 FW Jogging Operation Function •The motor rotates while the input is turned ON. •Allocate 06 (JG) to the desired multi-function input.
4-43 Multi-step speed Multi-step speed terminals CF4 CF3 CF2 CF1 0th OFF OFF OFF OFF 1st ON 2nd ON OFF 3rd ON 4th ON OFF OFF 5th ON 6th ON OFF 7th ON 8th ON OFF OFF OFF 9th ON 10th ON OFF 11th ON 12th ON OFF OFF 13th ON 14th ON OFF 15th ON 8t Data Symbol Function name Status Description 06 JG Jogging operation ON Operates at the set jogging frequency. OFF Stop Available input terminals C001, C002, C003, C004, C005, C006 Required settings A002 = 01, A038 > b082, A038 > 0, A039 Parameter No. Function name Data Default setting Unit A038 Jogging frequency 0.00/Starting frequency to 9.99 6.00 Hz A039 Jogging stop selection 00: Free-run stop 01: Deceleration stop 02:
DC injection braking stop 00 Hz