4-2 Function Mode 4 Functions *1. The Inverter's rated current is "1000". *2. The second decimal place is ignored when the value is over 10000 (100.0 seconds). 4-84 Register No. Function name Parameter No. R/W function Data Resolution 0097h Not used 0098h Starting frequency b082 R/W 5 to 99 0.1 [Hz] 0099h Carrier frequency b083 R/W 20 to 140 0.1 [kHz] 009Ah Initialization selection b084 R/W 0: Clears the trip monitor 1: Initializes data 2: Clears the trip monitor and initializes data 009Bh Initialization parameter selection b085 R/W Set "0" only. 009Ch Frequency conversion coefficient b086 R/W 1 to 999 0.1 009Dh STOP key selection b087 R/W 0: Enabled 1:
Disabled 009Eh Free-run stop selection b088 R/W 0: 0-Hz start 1: Frequency pull-in restart 009Fh Usage rate of regenerative braking function b090 R/W 0 to 1000 0.1 [%] 00A0h Stop selection b091 R/W 0: Deceleration → Stop 1: Free-run stop 00A1h Cooling fan control b092 R/W 0: Always ON 1: ON only during RUN (including 5 minutes after power on/stop) 2: Depends on the fin temperature 00A2h Regenerative braking function operation selection b095 R/W 0: Disabled 1: Enabled (disabled during stop) 2: Enabled (enabled during stop) 00A3h Regenerative braking function ON level b096 R/W 330 to 380/660 to 760 1. [V] 00A4h Overvoltage LAD stop function b130 R/W 0: Disabled 1:
Enabled 00A5h Overcurrent suppression function b140 R/W 0: Disabled 1: Enabled