— Supermicro SuperWorkstation 5046A-X User's Manual (1.0a)

Chapter 6: Advanced Chassis Setup 6-2 Front Control Panel The front control panel must be connected to the JF1 connector on the serverboard to provide you with system status and alarm indications. A ribbon cable has bundled these wires together to simplify this connection. Connect the cable from JF1 on the serverboard (making sure the red wire plugs into pin 1) to the appropriate comnnector on the front control panel PCB (printed circuit board). Pull all excess cabling over to the control panel side of the chassis. The LEDs on the control panel inform you of system status - see Figure 6-2 for details. See Chapter 5 for details on JF1. Figure 6-2.

Front Control Panel LEDs Power Indicates power is being supplied to the system. HDD Indicates IDE device and hard drive activity. On the SC743TS-865BP-SQ, this LED indicates SAS/SATA hard drive activity when fl ashing. NIC1 1 Indicates network activity on LAN port 1. NIC2 Indicates network activity on LAN port 2 2 Overheat/Fan Fail When this LED fl ashes, it indicates a fan failure. When on continuously it indicates an overheat condition (see Chapter 3 for details). Power Fail Indicates a power supply fan failure. An alarm will also sound, which can be turned off with the reset switch on the back of the power supply. 6-3