4-1 Monitor Mode Power ON Time Monitor [d017] Displays the total power ON time of the Inverter. (Display) 0. to 9999. : Displays in increments of 1 hour. 1000 to 9999 : Displays in increments of 10 hours. 100 to 999 : Displays in increments of 1000 hours. Fin Temperature Monitor [d018] 4 Displays the temperature of the fin inside the Inverter. (Display) 0.0 to 200.0: Displays in increments of 0.1 ° C. Functions Motor Temperature Monitor [d019] •Displays the temperature of the thermistor connected between the control circuit terminals TH and SC. •Use thermistor PB-41E (SHIBAURA ELECTRONICS). •Set thermistor selection b098 to "02" (NTC enabled). (Display) 0.0 to 200.0:
Displays in increments of 0.1 ° C. Note: When b098 = "01" (PTC enabled), the motor temperature monitor is disabled. Life Assessment Monitor [d022] •The LED lighting position indicates a life assessment result. The following two items can be monitored: 1: Main circuit board capacitor service life 2: Cooling fan rpm reduction Life assessment Normal 2 1 Note 1: The capacitor service life is calculated every 10 minutes. If the Inverter is turned on/off frequently within this interval, the capacitor service life cannot be correctly diagnosed. Note 2: While the cooling fan is stopped with b092 set to "01", the cooling fan rpm is judged as being normal.
Pulse Counter Monitor [d028] You can monitor a total pulse count of multi-function input function pulse counter 74 (PCNT). 4-5