omron — Display Selection

4-2 Function Mode Display Selection •You can change the items to be displayed on the Digital Operator. 4 Functions „ Individual Display of Functions •If a specific function is not selected, its relevant parameter is not displayed. •For details on the display requirements, refer to the following table. 4-53 Parameter No. Function name Data Default setting Unit b037 Display selection 00: Complete display 01: Individual display of functions 02: User setting 03: Data comparison display 04: Basic display 04  U001 to U012 User selection no: No allocation __ no  d001 to P131: Select the code you want to display. (Among all codes. Note that P100 to P131 cannot be used.) No.

Display requirements Parameters displayed when the requirements are met 1 A001 = 01 A005, A006, A011 to A016, A101, A102 A111 to A114, C081 to C083, C121 to C123 2 A001 = 10 A141 to A143 3 A002 = 01, 03, 04, 05 b087 4 A017 = 01 d025 to d027, P100 to P131 (Note that P100 to P131 cannot be used.) 5 A041 = 01 A046, A047 6 A044 = 00, 01 A041, A042, A043 7 A044 = 03, 04, 05 H002, H005, H050 8 A044 = 04 H060, H061 9 A044 = 03, 04, 05, and H002 = 00 H020 to H024 10 A044 = 03, 04, 05, and H002 = 01, 02 H030 to H034 11 Either of A044 or A244 = 03, 04, 05 d008 to d010, d012, b040 to b046, H001, H070 to H073 12 Either of A044 or A244 = 02 b100 to b113 13 A051 = 01, 02 A052, A056 to A058 14 A051 = 01, 02 A053 to A055, A059 15 A071 = 01, 02 d004, A005, A006, A011 to A016, A072 to A078 A101, A102, A111 to A114, C044, C052, C053, C081 to C083, C121 to C123 16 A076 = 10 A141 to A143 17 A094 = 01, 02 A095, A096 18 A097 = 01, 02, 03, 04 A131 19 A097 = 01, 02, 03, 04 A132 20 Any of b012, b212, and b312 = 02 b015 to b020