4-4 Communication Function Checks if a set value can be stored in EEPROM. •Transmission frame Frame format 4 Functions •Response frame Frame format Negative response: Refer to page 4-151. Stores a set value in EEPROM. •Transmission frame Frame format 4-150 STX Station No. Command BCC CR Description Data size Setting STX Control code (Start of TeXt) 1 byte STX (0x02) Station No. Station No. of the target Inverter 2 bytes 01 to 32 Command Transmission command 2 bytes 09 BCC Block check code 2 bytes Exclusive OR from station No. to data. (Refer to page 4-153.) CR Control code (Carriage Return) 1 byte CR (0x0D) STX Station No.
ACK Data BCC CR Description Data size Setting STX Control code (Start of TeXt) 1 byte STX (0x02) Station No. Station No. of the target Inverter 2 bytes 01 to 32 ACK Control code (ACKnowledge) 1 byte ACK (0x06) Data Data 2 bytes 01: Enabled BCC Block check code 2 bytes Exclusive OR from station No. to data. (Refer to page 4-153.) CR Control code (Carriage Return) 1 byte CR (0x0D) STX Station No. Command BCC CR Description Data size Setting STX Control code (Start of TeXt) 1 byte STX (0x02) Station No. Station No. of the target Inverter 2 bytes 01 to 32 Command Transmission command 2 bytes 0A BCC Block check code 2 bytes Exclusive OR from station No. to data.
(Refer to page 4-153.) CR Control code (Carriage Return) 1 byte CR (0x0D)