4-4 Communication Function 4 Functions Note 1: The Inverter's rated current is "1000". Note 2: If the set value is "10000" (100.0 sec) or more, the value in the second decimal place is ignored. 4-169 Register No. Function name Function code R/W Monitor and setting parameters Resolution 0001h Output frequency setting/monitor F001 (HIGH) R/W 0 to 40000 (Enabled when A001 = 03) 0.01 [Hz] 0002h F001 (LOW) R/W 0003h Inverter status A R 0: Initial status 1: Vdc establishment wait time 2: Stop 3: RUN 4: Free-run stop 5: Jogging 6: DC injection braking 7: Frequency matching 8: Retry 9: During UV 10: Trip 11: Undervoltage 0004h Inverter status B R 0: During stop 1: During RUN 2:
During trip 0005h Inverter status C R 0: 1: Stop 2: Deceleration 3: Constant speed 4: Acceleration 5: Forward 6: Reverse 7: Forward to reverse 8: Reverse to forward 9: Forward run start 10: Reverse run start 0006h PID feedback R/W 0 to 10000 0.01 [%] 0007h to 0010h Not used 0011h Fault frequency monitor d080 R 0 to 65530 1 [time]