3-7 Parameter List 3 Operation * 2nd/3rd control is displayed when "SET(08)/SET3(17)" is allocated to one of multi-function inputs from C001 to C008. 3-26 Parameter No. Function name Monitor or data range Default setting Changes during operation Unit Page V/f characteristics A046 Automatic torque boost voltage compensation gain 0. to 255. 100. Yes 4-20 A246 * 2nd automatic torque boost voltage compensation gain 0. to 255. 100. A047 Automatic torque boost slip compensation gain 0. to 255. 100. Yes A247 * 2nd automatic torque boost slip compensation gain 0. to 255. 100. DC injection braking A051 DC injection braking selection 00: Disabled 01: Enabled 02:
Frequency control [A052 set value] 00 No 4-24 4-107 A052 DC injection braking frequency 0.00 to 99.99 100.0 to 400.0 0.50 No Hz 4-24 A053 DC injection braking delay time 0.0 to 5.0 0.0 No s 4-25 DC injection braking A054 DC injection braking power 0. to 100. 50. No % A055 DC injection braking time 0.0 to 60.0 0.5 No s A056 DC injection braking method selection 00: Edge operation 01: Level operation 01 No A057 Startup DC injection braking power 0. to 100. 0. No % A058 Startup DC injection braking time 0.0 to 60.0 0.0 No s A059 DC injection braking carrier frequency 0.5 to 15.0 5.0 No kHz Upper/Lower limiter, Jump A061 Frequency upper limit 0.00/Frequency lower limit to Max.
frequency 0.00 No Hz 4-28 A261 * 2nd frequency upper limit 0.00/2nd frequency lower limit to 2nd Max. frequency 0.00 A062 Frequency lower limit 0.00/Starting frequency to Frequency upper limit 0.00 No Hz A262 * 2nd frequency lower limit 0.00/Starting frequency to 2nd frequency upper limit 0.00