omron — Extended Function Mode

3-7 Parameter List 3 Operation * 2nd/3rd control is displayed when "SET(08)/SET3(17)" is allocated to one of multi-function inputs from C001 to C008. 3-31 Parameter No. Function name Monitor or data range Default setting Changes during operation Unit Page Electronic Thermal b012 Electronic thermal level 0.20 × Rated current to 1.00 × Rated current Rated current No A 4-46 b212 * 2nd electronic thermal level b312 * 3rd electronic thermal level b013 Electronic thermal characteristics selection 00: Reduced torque characteristics 01: Constant torque characteristics 02:

Free setting 00 No  b213 * 2nd electronic thermal characteristics selection b313 * 3rd electronic thermal characteristics selection b015 Free setting, electronic thermal frequency 1 0. to 400. 0. No Hz 4-47 b017 Free setting, electronic thermal frequency 2 b019 Free setting, electronic thermal frequency 3 b016 Free setting, electronic thermal current 1 0.0 to Rated current 0.0 No A b018 Free setting, electronic thermal current 2 b020 Free setting, electronic thermal current 3