4.7 Test Run Save the verified parameter settings. Change the access level or set a password to the drive to prevent accidental modification of parameter settings. ■ Backing Up Parameter Values: o2-03 Performing the following procedure stores all parameters settings to drive memory where they can later be recalled if necessary. Set o2-03 to “1” to save parameter changes. This saves all parameter settings, and then returns o2-03 to 0. The drive can now “recall” the saved parameters by performing a “user-initialization” (A1-03 = 1110). ■ Parameter Access Level: A1-01 Setting the Access Level for “Operation only” (A1-01 = 0) allows the user to access parameters A1- †† and U † - †† only.
Other parameters are not displayed. Setting the Access Level for “User Parameters” (A1-01 = 1) allows the user to access parameters that have been previously saved as Preferred Parameters. This is helpful when displaying only the relevant parameters for a specific application. 160 OYMC TOEP C71060622-01-OY V1000 User Manual No. Parameter Name Description Setting Range Default Setting o2-03 User Parameter Default Value Allows storing of parameter settings as a User Initialization Selection. 0: Saved/Not set 1: Set Defaults - Saves current parameter settings as user default settings. 2: Clear All - Clears the currently saved user settings.
After saving the user parameter set value, the items of 1110 (User Parameter Initialize) are displayed in A1-03 (User Parameter Default Value). 0 to 2 0 A1-03 Initialize Parameters Selects a method to initialize the parameters. 0: No Initialize 1110: User Initialize (The user must first program and store desired settings using parameter o2-03) 2220: 2-Wire Initialization (parameter initialized prior to shipment) 3330: 3-Wire Initialization 5550: OPE4 Fault reset 0 to 5550 0 No. Parameter Name Description Setting Range Default A1-01 Access Level Selection Selects which parameters are accessible via the digital operator. 0: Operation only (A1-01, -04, and -06 can be set and monitored.
U parameters can be monitored) 1: User Parameters (Only those recently changed among application parameters A2-01 to -16 and A2-17 to -32 can be set and monitored) 2: Advanced Access Level (All parameters can be set and monitored) 0 to 2 2