1.2 Model Number and Nameplate Check Receiving 1 Three-Phase 400 V * Drives with these specifications do not guarantee complete protection for the specified environmental condition. Note: Refer to Component Names on page 30 for differences regarding enclosure protection types and component descriptions. OYMC TOEP C71060622-01-OY V1000 User Manual 27 No. Heavy Duty Normal Duty Max. Motor Capacity kW Rated Output Current A Max. Motor Capacity kW Rated Output Current A 20P7 0.75 5 1.1 6 21P5 1.5 8 2.2 9.6 22P2 2.2 11 3.0 12 24P0 4.0 17.5 5.5 19.6 25P5 5.5 25 7.5 30 27P5 7.5 33 11 40 2011 11 47 15 56 2015 15 60 18.5 69 No. Heavy Duty Normal Duty Max. Motor Capacity kW Rated Output Current A Max.
Motor Capacity kW Rated Output Current A 40P2 0.2 1.2 0.4 1.2 40P4 0.4 1.8 0.75 2.1 40P7 0.75 3.4 1.5 4.1 41P5 1.5 4.8 2.2 5.4 42P2 2.2 5.5 3.0 6.9 43P0 3.0 7.2 4.0 8.8 44P0 4.0 9.2 5.5 11.1 45P5 5.5 14.8 7.5 17.5 47P5 7.5 18 11 23 4011 11 24 15 31 4015 15 31 18.5 38