B.2 Parameter Table ◆ Control Mode Dependent Parameter Default Values The tables below list parameters that depend on the control mode selection (A1-02 for motor 1, E3-01 for motor 2). These parameters are initialized to the shown values if the control mode is changed. Table B.1 A1-02 (Motor 1 Control Mode) Dependent Parameters and Default Values Default setting value is dependent on parameter E5-01, Motor Code Selection. Default setting value is dependent on parameter o2-04, Drive Unit Selection. Values shown here are for 200 V class drives. Double the value when using a 400 V class drive.
OYMC TOEP C71060622-01-OY V1000 User Manual 371 Para- meter Description Setting Range Resolution Control Modes (A1-02) V/f (0) OLV (2) PM (5) b3-02 Speed Search deactivation current 0 to 200 1 % 120 100 – b8-02 Energy Saving gain 0.0 to 10.0 0.1 – 0.7 – C2-01 S-curve time at acceleration start 0.00 to 10.00 0.01 s 0.20 0.20 1.00 C3-01 Slip compensation gain 0.0 to 2.5 0.1 0.0 1.0 – C3-02 Slip compensation time constant 0 to 10000 1 msec 2000 200 – C4-01 Torque comp. gain 0.00 to 2.50 0.01 1.00 1.00 0.00 C4-02 Torque comp.
primary delay time 0 to 10000 1 msec 200 20 100 C6-02 Carrier frequency 1 to F 1 7 7 2 E1-04 Maximum output frequency 40.0 to 400.0 0.1 Hz 50.0 50.0 E1-05 Maximum output voltage 0.0 to 255.0 0.1 V 200.0 200.0 E1-06 Base Frequency 0.0 to 400.0 0.1 Hz 50.0 50.0 E1-07 Middle output frequency 0.0 to 400.0 0.1 Hz 2.5 3.0 – E1-08 Middle output freq. voltage 0.0 to 255.0 0.1 V 16.0 14.4 – E1-09 Minimum output frequency 0.0 to 400.0 0.1 Hz 1.3 0.5 E1-10 Minimum output voltage 0.0 to 255.0 0.1 V 12.0 3.0 – E1-11 Middle output frequency 2 0.0 to 400.0 0.1 Hz 0.0 0.0 – E1-12 Middle output freq.
voltage 2 0.0 to 255.0 0.1 V 0.0 0.0 – E1-13 Base voltage 0.0 to 255.0 0.1 V 0.0 0.0 – B L1-01 Motor protection selection 0 to 4 - 1 1 4 L3-20 Accel/Decel rate calculation rate 0.00 to 5.00 0.01 1.00 0.30 0.65 L3-21 Decel time at stall prevention during acceleration 0.00 to 200.00 0.01 1.00 1.00 2.50