omron — 4.3 The Drive and Programming Mode

4.3 The Drive and Programming Mode 4.3 The Drive and Programming Mode The drive functions are divided into two main groups accessible via the Digital LED Operator: Drive Mode: The Drive mode allows motor operation and parameter monitoring. Parameter settings cannot be changed when accessing functions in the Drive Mode ( Table 4.3 ). Programming Mode: The Programming Mode allows access to setup/adjust, verify parameters and Auto-Tuning. The drive prohibits changes in motor operation such as start/ stop when the Digital LED Operator is accessing a function in the Programming Mode.

Start-Up Programming & Operation Table 4.3 illustrates the different functions visible as the “Up arrow” is scrolled immediately after powering up the drive. Note: When b1-08 (Run Command Selection while in Programming Mode) is set to 1 (enabled), the drive can run even if the mode is switched to the programming mode. When setting b1-08 to 0 (disabled), the mode cannot be switched to the programming mode while the drive is running.

Table 4.3 Summary of Modes 4 93 Mode Group Description Key Press LED Digital Operator Display Drive Mode Functions (Motor operation and monitoring) Frequency Reference Display (Initial power-up state) Forward/Reverse Output Frequency Display Output Current Display Output Voltage Reference Monitor Display Verify Function Setup Group Parameters Programming Mode Functions (Changing parameters) All Parameters Auto-Tuning OYMC TOEP C71060622-01-OY V1000 User Manual 9