4.3 The Drive and Programming Mode 4.3 The Drive and Programming Mode The drive functions are divided into two main groups accessible via the Digital LED Operator: Drive Mode: The Drive mode allows motor operation and parameter monitoring. Parameter settings cannot be changed when accessing functions in the Drive Mode ( Table 4.3 ). Programming Mode: The Programming Mode allows access to setup/adjust, verify parameters and Auto-Tuning. The drive prohibits changes in motor operation such as start/ stop when the Digital LED Operator is accessing a function in the Programming Mode.
Start-Up Programming & Operation Table 4.3 illustrates the different functions visible as the “Up arrow” is scrolled immediately after powering up the drive. Note: When b1-08 (Run Command Selection while in Programming Mode) is set to 1 (enabled), the drive can run even if the mode is switched to the programming mode. When setting b1-08 to 0 (disabled), the mode cannot be switched to the programming mode while the drive is running.
Table 4.3 Summary of Modes 4 93 Mode Group Description Key Press LED Digital Operator Display Drive Mode Functions (Motor operation and monitoring) Frequency Reference Display (Initial power-up state) Forward/Reverse Output Frequency Display Output Current Display Output Voltage Reference Monitor Display Verify Function Setup Group Parameters Programming Mode Functions (Changing parameters) All Parameters Auto-Tuning OYMC TOEP C71060622-01-OY V1000 User Manual 9