omron — Diagnostic Boot Mode

E Vision MINI Diagnostic Boot Mode It is possible to configure the system to acquire its IP address via DHCP or to use a static IP address. Issue the following command with a ‘0’ for static IP or a ‘1’ for DHCP. [SAFE-KERNEL] BP_UpdateDHCP(0) Additional Boot Parameters BP_UpdateCameraName(cameraName) where cameraName is a double-quoted string representing the new camera name. Function: Allows you to change the name of the smart camera. BP_UpdateLaserOn(state) where state = 0 or 1 Function: Allows you to disable or enable the state of the targeting laser during image acquisition. The actual display of the targeting laser is a logical AND of job settings with this parameter.

Note that when the laser is disabled it is still possible to turn the laser on when a job is not running by issuing the serial command target 1 (Turn Target On). BP_UpdateGreenFlash(state) where state = 0 or 1 Function: Allows you to disable the flash-on-pass feature to eliminate green flash interference during color image processing. Vision MINI Smart Camera Guide E-3