omron — 5-2-1 Unit Configuration

5 How To Use NA Sample Pages This section describes how to use the NA sample pages. 5 - 1 NA Sample Pages Functions The NA sample pages include the following functions: 5 - 2 System Configuration The system configuration that enables to use this project is shown below. To use this project, adjust the actual system configuration to the one specified for the project. NA-series Programmable Terminal The following table shows the controller unit configuration. 10 Function Description Calibration Calibrates the load cell input unit from the NA-series programmable terminal display. Allows both the actual load calibration and the equivalent input calibration.

Disconnection detection Executes the function to detect sensor disconnection of the load cell input unit and displays the result of the execution on the NA-series programmable terminal display. Feed weighing control Executes controlling of feed weighing. Allows setting of control parameters and monitoring of control result/state on the NA-series programmable terminal display. 5-2-1 Unit Configuration Unit model Model number Setting EtherCAT master CPU Unit NJ501-1500 EtherCAT Coupler Unit NX-ECC203 Node Address 1 NX-series Load Cell Input Unit NX-RS1201 NX Unit No. 1 NX-series Digital Output Unit NX-OD3153 NX Unit No. 2 Programmable Terminal NA5-9W001□ -