omron — 5-3-1 Calibration

3. You can perform Standard Weight Settings, Zero Calibration, and Span Calibration on this page. The page also indicates the state of the load cell input unit. Implement calibration according to the procedure described in NX-Series Load Cell Input Units User's Manual (W565). 12 Name Description Standard Weight Settings Pressing the “Standard Weight Settings” button after setting a value in Standard Weight at the upper right specifies the standard weight for the load cell input unit. Execute Zero Calibration Pressing the “Execute Zero Calibration” button makes the load cell input unit execute zero calibration.

Execute Span Calibration Pressing the “Execute Span Calibration” button makes the load cell input unit execute span calibration. Stable status indicator Indicates the stable status of the load cell input unit as follows: Lit: Detected the status where the gross weight value / force measurement value of the load cell input unit is stable. Not lit:Not detected the status where the gross weight value / force measurement value of the load cell input unit is stable. Net Weight display Indicates a net weight value of the load cell input unit. Total Weight display Indicates a gross weight value of the load cell input unit.