Supermicro X8DTG-QF+ — X8DTG-QF+ 1.0.indb

Chapter 2: Installation Overheat (OH)/Fan Fail/PWR Fail/UID LED Connect an LED cable to OH/Fan Fail/FP UID connection on pins 7 and 8 of JF1 to provide advanced warnings of chassis overheat or fan failure. It also works as the front panel UID LED indicator. The Red LED takes precedence over the Blue LED by default. Refer to the table on the right for pin defi nitions. OH/Fan Fail Indicator Status State Defi nition Off Normal On Overheat Flash- ing Fan Fail Power Fail LED The Power Fail LED connection is located on pins 5 and 6 of JF1. Refer to the table on the right for pin defi nitions. A. Front UID LED (Blue) B. OH/Fail/PWR Fail LED (Red) C. PWR Supply Fail X8DTG-QF+ Rev.

1.10 1 2 Power Button Ground Reset Button Ground 3.3V PWR Fail LED C A B Blue- (Blue_LED_Cathode (UID)) Red-(OH/Fan Fail/ PWR Fail/UID LED) NIC2 (Activity) LED NIC2 (Link) LED NIC1(Link) LED NIC1 (Activity) LED ID_UID SW/3.3V SB HDD LED FP Power LED 3.3V No Connection x x +5V STBY 19 20 2-17 OH/Fan Fail/PWR Fail/UID LED Pin Defi nitions (JF1) Pin# Defi nition 7 Blue- (Blue LED Cathode) (UID) 8 Red- (OH/Fan Fail/PWR Fail/ UID LED) PWR Fail LED Pin Defi nitions (JF1) Pin# Defi nition 5 3.3V 6 PWR Supply Fail