F2B ENGINE 109 T RAKKER E URO 4/5 PRINT603.93. 641  Print 603.93.641 Base q November 2006 543210 Electromagnetic fan drive Figure 216 78842 ELECTROMAGNETIC FAN DRIVE SECTION The electro-magnetic fan drive action depends on: - the coolant temperature; - the climate control system fluid pressure (if any); - the slowing down action of the intarder on (if any). Coolant temperature for: - engagement 93 C - disengagement 88 C With climate control system Climate control system fluid pressure: - 2nd speed engagement 22 bar With intarder With braking power below 41% of maximum power. Coolant temperature for:

- 2nd speed engagement 93 C - disengagement 88 C With braking power over 41% of maximum power: Coolant temperature for: - 2nd speed engagement 85 C - disengagement 80 C Using a feeler gauge, check the gap between the anchor assembly (2) and the pulley (1), it must be no greater than 2.5 mm. As to the description of the electro-magnetic joint operation and servicing, see the Volume 3. Figure 217 92826 ELECTROMAGNETIC FAN DRIVE SECTION NEW VERSION 543210 Water pump Figure 218 44915 WATER PUMP SECTION The water pump consists of: rotor, seal bearing and control pulley. NOTEMake sure that the pump casing has no cracking or water leakage; otherwise, replace the entire pump.