Lenze — 5.3.2 Devices for 400/500V-mains

5 5.3 5.3.2 Multi-axis controllers Rated data Devices for 400/500V-mains 5.3.2 Devices for 400/500V-mains 5.3.2.1 Operation on 230 V AC mains I aN2 Rated value of permanent output current at a frequency of ≥ 0 Hz I aM2 Maximum output current (overload current) z Periodic load change of 0.5 s with I aM2 and recovery time of 4.5 s with 75 % I aN2 I aN4 , I aN8, I aN16 Rated value of permanent output current at a frequency of ≥ 5 Hz (reduce to 0.66 * I aNx for 0 ...

5 Hz) I aM4 , I aM8 Maximum output current (overload current) z Periodic load change of 0.5 s with I aMx and recovery time of 4.5 s with 75 % I aNx z Can be achieved using the setting ”x kHz fixed” in C00018 bold Nominal value I aN  5.3-2 EDS94SPP101 EN 3.1-04/2007 Basis of the data Mains Rated voltage UDC [V] Voltage range UDC [V] Frequency range [Hz] 2/PE DC 325 260 - 0 % ... 370 + 0 % - Input current at IaN8 Output power Motor power (typical) (without external mains choke) 8 kHz, U, V, W 8 kHz, 4 pol.

ASM Type IDC [A] SaN8 [kVA] PaN [kW] PaN [hp] E94AMxE0024 2.6 0.6 0.18 0.25 E94AMxE0034 4.3 1.0 0.37 0.5 E94AMxE0044 6.7 1.6 0.75 1 E94AMxE0074 12.1 2.8 1.5 2 E94AMxE0094 15.4 3.7 2.2 3 E94AMxE0134 20.6 5.2 3 4 E94AMxE0174 25.7 6.6 4 5.5 E94AMxE0244 35.5 9.4 5 7.5 Output currents [A] at switching frequency 2 kHz 4 kHz 8 kHz 16 kHz Type IaN2 IaM2 IaN4 IaM4 IaN8 IaM8 IaN16 E94AMxE0024 1.9 6.0 1.9 6.0 1.5 4.8 1.1 E94AMxE0034 3.1 10.0 3.1 10.0 2.5 8.0 1.9 E94AMxE0044 5.0 16.0 5.0 16.0 4.0 12.8 3.0 E94AMxE0074 8.8 21.0 8.8 21.0 7.0 16.8 5.3 E94AMxE0094 11.7 28.0 11.7 28.0 9.3 22.4 7.0 E94AMxE0134 16.3 39.0 16.3 39.0 13.0 31.2 9.8 E94AMxE0174 20.6 49.5 20.6 49.5 16.5 39.6 12.4 E94AMxE0244 29.4 70.5 29.4 70.5 23.5 47.0 17.6