Lenze — 4.3.4 Operation at rated mains voltage 500 V

Single-axis controllers Rated data (devices for 400/500V mains) Operation at rated mains voltage 500 V 4 4.3 4.3.4 Rated values for internal brake chopper I BRmax , P BRmax Periodic load change of 0.5 s and recovery time of 4.5 s R Bmin Nominal value, ±10 % Permanent current, r.m.s. R.m.s.

value - important for cable dimensioning  4.3-13 EDS94SPP101 EN 3.1-04/2007 Switching threshold (adjustable) Minimum brake resistor Peak current Peak braking power Continuous current RMS Continuous braking power Type UBRmax [V] RBmin [Ω] IBRmax [A] PBRmax [kW] IBRd [A] PBd [kW] E94ASxE0024 790 82 9.6 7.6 4.3 1.5 E94ASxE0034 790 82 9.6 7.6 4.3 1.5 E94ASxE0044 790 47 16.8 13.3 6.9 2.3 E94ASxE0074 790 47 16.8 13.3 8.1 3.1 E94ASxE0134 790 27 29.3 23.1 14.4 5.5 E94ASxE0174 790 18 43.9 34.7 20.6 7.6 E94ASxE0244 790 18 43.9 34.7 24.8 11.1 E94ASxE0324 790 18.0 43.9 34.7 28.9 15.0 E94ASxE0474 790 15.0 52.7 41.6 38.4 22.0 E94ASxE0594 790 15.0 52.7 41.6 44.8 30.0 E94ASxE0864 790 7.5 105.3 83.2 77.5 45.0 E94ASxE1044 790 7.5 105.3 83.2 85.7 55.0 E94ASxE1454 790 5.0 158 125 87 37.4 E94ASxE1724 790 4.3 184 145 101 43.5 E94ASxE2024 790 3.5 226 178 124 53.5 E94ASxE2454 790 2.8 282 223 154 66.9 E94ASxE2924 790 2.3 343 271 188 81.4 E94ASxE3664 790 1.8 451 357 247 107 E94ASxE4604 790 1.4 564 446 289 117 E94ASxE5724 790 1.2 658 520 312 117 E94ASxE6354 790 1.1 718 567 327 117 E94ASxE6954 790 1.1 718 567 327 117