sinee — A90 User Manual

User Manual of A90 Series Inverter 100 F12.39 LCD large-line display parameter 2 0.00 - 99.99 18.06 ● F12.40 LCD large-line display parameter 3 0.00 - 99.99 18.09 ● F12.41 Options of UP/DOWN zero crossing 0: prohibit zero crossing 1: allow zero crossing 0 ○ F12.45 UP/DOWN function options of keyboard Commu nication * Analog quantity Digital frequency Multi-seg ment speed 1 ○ 0/1 * 0/1 0/1 0/1 0: invalid 1: valid F13 Torque control parameter group F13.00 Speed/torque control options 0: Speed control 1: Torque control 0 ○ F13.01 Options of torque setting source 0: digital torque setting F13.02 1: AI1 2: AI2 3: retention 4:VP 5: retention 6:

Communication setting (Full range of the items 1-6, corresponding to F13.02 digital torque setting) 0 ○ F13.02 Digital torque setting -200.0 to 200.0 (100.0 = the rated torque of motor) % 100.0 ● F13.03 Multi-segment torque 1 -200.0 - 200.0 % 0.0 ● F13.04 Multi-segment torque 2 -200.0 - 200.0 % 0.0 ● F13.05 Multi-segment torque 3 -200.0 - 200.0 % 0.0 ● F13.06 Torque control acceleration and deceleration time 0.00 - 120.00 s 0.05 ● F13.07 Reserved F13.08 Upper frequency limit options of torque control 0: set by F13.09 1: AI1 2: AI2 6: communication percentage setting 7: direct communication setting 0 ○ F13.09 Upper frequency limit of torque control 0.00 to maximum frequency F00.16 Hz 50.00 ●