User Manual of A90 Series Inverter 7.19 Fault Record Parameter Group of F19 Group This group of parameters is used only to view the types of last three faults of the inverter and the inverter status at the time of failure. They cannot be changed. The function codes related to the last fault are as follows.
248 F18.41 ~ F18.50 Reserved F18.51 PID output -300.0 to 300.0 % F18.51 PID output -100.0 - 100.0 % F18.60 Inverter temperature -40 to 200 °C F18.67 Cumulative energy saving MWH 0 - 65535 MW h F18.68 Cumulative energy saving KWH 0.0 - 999.9 kW h F18.69 High cumulative cost saving (*1000) 0 - 65535 F18.70 Low cumulative cost saving 0.0 - 999.9 F18.71 Power-frequency power consumption MWH 0 - 65535 MW h F18.72 Power-frequency power consumption KWH 0.0 - 999.9 kW h Function Function code Default Parameter description Unit Attribute code name setting F19.00 Last fault category Display the type of the last fault, as detailed in Table 7-22 List of Fault Types.
0 × F19.01 Output frequency in failure Display the output frequency in the last fault. Hz 0.00 × F19.02 Output current in failure Display the output current in the last fault. A 0.00/0.0 × F19.03 Bus voltage in failure Display the bus voltage in the last fault. V 0 × F19.04 Running status in failure Display the running status in the last fault, as detailed in Table 0 ×